VRW-300AL-3 Thermal Deformation Vicat Softening Point Temperature Tester

NO:3-station working position, Digital Display, Vertical Type, Sample holder lifting automatically
  • WDW-5/10/20KN Computerized Electronic Plastic Universal Testing Machine
  • QC-II Notch Depth Size Measuring Instrument
  • FTH-9901 Carbon Black Content Tester
  • XJLS-50 digital display tensile impact testing machine

Share With:

We"re here to help:
Easy ways to get the answers you need.
Send E-mail WhatsAPP/Wechat
+86-15254140530
1. Simple Introduction
It is mainly used for the determination of thermal deformation temperature and Vicat softening point temperature of non-metallic materials such as plastics, hard rubber, nylon, electrical insulating materials, long fiber reinforced composite materials, high-strength thermosetting laminate materials, etc. It is easy to operate and precise in control. It is a highly intelligent testing instrument, which is widely used in colleges and universities, scientific research units and product quality supervision and inspection units.
 
2. Test Standards
Comply with GB/T 1633, GB/T 8802, GB/T 1634, ISO 2507, ISO 75, ISO 306, ASTMD 1525, ASTMD 648 and other standards.
 
3. Characteristics
3.1 Single-chip control, Chinese characters LCD display temperature. Real-time button storage and query of test results.
3.2 Multiple safety protections: mechanical temperature upper limit protection switch and software temperature upper limit protection to ensure safe and stable operation of the test.
3.3 High-precision measurement and control system: the use of high-performance temperature sensor and advanced capacitive digital display dial indicator to accurately measure the small changes of the sample, the use of advanced PID algorithm and full photoelectric isolation phase modulation module for heating control, to ensure the heating The rate error is less than 0.5°C.
 
4. Technical Parameters
Model VRW-300AL-3
Temperature Control Range Room Temperature ~ +300°C
Maximum temperature error ±0.5℃(50℃ heating rate)
±1℃(120℃ heating rate)
Heating rate 50℃/h、120℃/h
Temperature measurement point  1
Test Stations  3
Deformation measurement range -0.1~10mm
Maximum deformation error ±0.01mm
Specimen supporting span 64mm、100mm
The sample holder is automatically raised and lowered, and the coefficient of thermal expansion of the sample holder itself is less than 0.005/100°C (the key point, which directly affects the experimental results)
Use medium: methyl silicone oil or transformer oil
Cooling method: natural cooling above 150℃, water cooling or natural cooling below 150℃